High-Frequency/High-Current Meter

image:High-Frequency/High-Current Meter

The high-frequency/high-current meter LCA-101 does not use a metal core but a clamp, eliminating the problem of iron loss and saturation distorting linearity affecting results.
There are two sensors, clamp and flexible, enabling measurement of an object of any shape.

Use

  • Induction heater current measurement and control
  • High-frequency CT
  • Measurement of current circulation around structures
  • Measurement of earth current
  • Measurement of lightning surges
  • Measurement of rectifier current share
  • Measurement of glass conductivity
  • Measurement of high-frequency welding current
  • Measurement of plasma current
  • Measurement and control of all types of high-frequency current

Specification

Measurement range 10A~120A
Mains to 1MHz
Accuracy FS±0.5%~±3%
Outer dimensions W260mm×D270mm×H105mm Option 4~20mA BCD output
Sensor Clamp
Flexible
Power AC100V to AC220V (Please specify) 50W
Weight Approx. 3kg Display maximum 1999 or 19999 (option)